Record s20531
  • Age: 70
  • Sex: Male
HR
Updating...
Paper speed: Zoom: mm/second
Amp: mm/mV
Show III, aVR, aVL, aVF
Show 12 leads
  • Filters
    • Smooth
    • Baseline correction
  • QRS intervals
    • Heart rate
    • RR intervals
  • Paper speed
    • 5 mm/second
    • 10 mm/second
    • 25 mm/second
    • 50 mm/second
    • 100 mm/second
  • Amplitude
    • 2 mm/mV
    • 5 mm/mV
    • 10 mm/mV
    • 20 mm/mV
    • 40 mm/mV
  • Show/hide leads
    • -
    • Digital calipers mode
    • -
    • Zoom in
    • Zoom out
    • -
    • Increase channels spacing
    • Decrease channels spacing
    • -
    • Enter fullscreen
      Exit fullscreen
    Save as:

    Additional data

    • Comments

        This record shows intermittent LBBB with numerous changes in conduction.
        At some times the alteration in conduction was so rapid that the ST
        deviation function showed only low-amplitude oscillations, and these
        were "tracked out" by the annotators (see 16:26:10 in lead 1). No
        ischemia was found in this record. The variation in QRS shape also
        resulted in fiducial point slip and subsequent ST-level deviations
        that were not specially annotated but were tracked out.
    • Diagnoses: Dilated cardiomyopathy
    • Treatment

      • Medication: No
      • Balloon Angioplasty: No data
      • Coronary Artery bypass Grafting: No data
    • History

      • Comments: Palpitations
      • Hypertension: No
      • Left ventricular hypertrophy: No
      • Cardiomyopathy: yes, dilated cardiomyopathy
      • Valve disease: No
      • Electrolyte abnormalities: No
      • Hypercapnia, anemia, hypotension, hyperventilation: No
      • Atrioventricular nodal conduction delay: No
      • Intraventricular conduction block: Intermittent
      • Previous Myocardial Infarction: No data
      • Previous tests

        • ECG stress test

          • Thallium/Stress echo: No data
          • Left ventricular function: Abnormal - Left ventricular ejection fraction 38%
          • Echocardiogram: No data
          • Coronary Arteriography: Normal coronary tree
          • Baseline ECG: Left bundle branch block
      • Holter Recording

        • Date: 15/04/1999
        • Recorder: Remco